Application
Applications The CAN bus cable for cable tracks has FEP core insulation and very good oil resistance. It is used in the exchange of digital information, Controller Area Network (CAN), for faster data transmission.
Cable structure
Conductor
Cross-section | 0.34mm2/2PR |
---|
Structure | 19/0.15±0.005mm |
---|
Material | Stranded Bare Copper |
---|
Insulation
Insulation O.D | 2.10±0.10mm |
Material | Foam PE |
Color | White,Brown, Blue,Red |
Shielded
Braid Material | Tinned copper |
Coverage | 80% |
Jacket
Jacket O.D | 8.50±0.20mm |
Material | FRPVC |
Color | Violet |
Technical data
Electrical parameters
Inner Conductor DC Resistance | ≤55.4Ω/km |
Characteristic Impedance | 120 ±10%Ω |
Test Voltage | 1kV/1min,no breakdown |
Velocity of Propagation | 78% |
physical parameters
Min. Bending Radius | Fixed installation:8D, Mobile installation: 15D |
Flame Resistance | IEC60332-1-2 |
Operating temperature | Fixed installation:-40℃ to +80℃, Mobile installation:-30℃ to +70℃ |