Application
Harsh environment, outdoors, data transmission applications such as Profibus DP or PA, Instrumentation and computer cable, etc. exposure to temperature extremes, humidity/moisture, dust, and oil.
Cable structure
Conductor
Cross-section | 22AWG/2C |
---|
Structure | 7/0.25±0.005mm |
---|
Material | Bare copper |
---|
Insulation
Insulation O.D | 2.55±0.10mm |
Material | Foam PE |
Color | Red, Green |
Inner Jacket
Braid Material | 5.80±0.20mm |
Coverage | LSZH |
Shielded
Braid Material | Tinned copper |
Coverage | ≥80% |
Outer Jacket
Jacket O.D | 8.00±0.20mm |
Material | LSZH |
Color | Violet |
Technical data
Electrical parameters
Inner Conductor DC Resistance | ≤55.4Ω/km |
Characteristic Impedance | 150 ±15Ω@3~20Mhz |
Capacitance Conductor to Conductor | Nom. 28pF/m@800Hz |
Test Voltage | 2000V/1min,no break down |
Velocity of Propagation | 78% |
Operating Voltage | 100/100V |
physical parameters
Min. bending Radius | Fixed installation: 9×D |
Temperature Range | -40℃ to +80℃ |
Flame Resistance | IEC 60332-3-24 |
Halogens and Acidity | IEC 60754-1/2 |