Application
Applications The CAN bus cable for cable tracks has FEP core insulation and very good oil resistance. It is used in the exchange of digital information, Controller Area Network (CAN), for faster data transmission.
Cable structure
Conductor
Cross-section | 22AWG/2PR |
---|
Structure | 7/0.254±0.005mm |
---|
Material | Tinned Copper |
---|
Insulation
Insulation O.D | 2.0±0.10mm |
Material | Foam PE |
Color | Blue, Brown, Black, Violet |
Twist Pair
Color | Blue &Brown,Black&Violet |
O.D | 4.0±0.20mm |
Shielded
Braid Material | Tinned copper |
Coverage | 65% |
Outer Jacket
Jacket O.D | 10.60±0.20mm |
Material | TPV |
Color | Black |
Technical data
Electrical parameters
Inner Conductor DC Resistance | ≤57.4Ω/km |
Outer Conductor DC Resistance | ≤96.7Ω/km |
Characteristic Impedance | 120 ±10%Ω |
Capacitance Conductor to Conductor | Nom. 36pF/m |
Capacitance Conductor to Shield | Nom. 69pF/m |
Velocity of Propagation | 78% |
Operating Voltage | Max 300V |
physical parameters
Temperature Range | -20℃ to +70℃ |
Sun Resistance | 720H |
Flame Resistance | IEC60332-1-2 |
Oil Resistance | Engine Oil |